Table 4.3 Noise
Monitoring Parameters, Duration and Frequency
Contract No. |
Monitoring Stations |
Parameters[2] |
Duration |
Frequency |
Measurement |
|
ND/2019/06 |
CP-FLN-NMS1[3] |
L10(30 min.) dB(A) L90(30 min.) dB(A) Leq(30 min.)dB(A) (as six consecutive Leq, 5min readings) |
0700-1900 hours on normal weekdays |
Once per week |
Façade |
|
ND/2019/04 |
||||||
ND/2019/05 |
||||||
CP-FLN-NMS2[4] |
||||||
ND/2019/01 |
CP-KTN NMS2[5] |
Free-field[1] |
||||
CP-KTN NMS3[6] |
||||||
ND/2019/01 |
CP-KTN NMS5 |
|||||
ND/2019/02 |
CP-KTN-NMS6 |
Façade |
Remarks:
[1]:
Correction of +3dB (A) for free-field measurement.
[2]: A-weighted equivalent
continuous sound pressure level (Leq). It
is the constant noise level which, under a given situation and time period, contains the same acoustic energy as the actual
time-varying noise level.
L10 is the level
exceeded for 10% of the time. For 10% of the time, the sound or noise has a
sound pressure level above L10.
L90 is the level
exceeded for 90% of the time. For 90% of the time, the noise level is above
this level.
[3]:
Since the distance between monitoring station and site boundary of ND/2019/03
under EP-473/2013/A exceeds 300m, the monitoring station is not applicable to
ND/2019/03.
[4]:
Since the distance between monitoring station and site boundary of ND/2019/03
and ND/2019/04 under EP-473/2013/A
exceeds 300m, the monitoring station is not applicable to ND/2019/03 and ND/2019/04.
[5],[6]: Since the distance between monitoring station and site boundary of ND/2019/03 under EP-468/2013/A exceeds 300m, the monitoring station is not applicable to ND/2019/03.